[Beowulf] test network link quality?
Many of your questions may have already been answered in earlier discussions or in the FAQ. The search results page will indicate current discussions as well as past list serves, articles, and papers.
David Mathog mathog at caltech.eduFri Apr 2 12:13:37 PDT 2010
- Previous message: [Beowulf] test network link quality?
- Next message: [Beowulf] which 24 port unmanaged GigE switch?
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
> we've noticed that occasionally cables of dubious quality > pop up and cause issues with packet flow in either one or both > directions. That's one sort of error that would be nice to be able to detect, especially in cases where the error is subtle. > Using iperf we can see nodes that don't perform properly, > and we notice a lot of problems that don't show up with simple ping > tests. Iperf is not exactly what I was looking for, but close. An iperf report looks like: [ 3] 0.0-10.0 sec 1.25 MBytes 1.05 Mbits/sec 0.002 ms 0/ 893 (0%) For comparison of (low) error rates, all that's useful is the 0/893. The numbers in this run are too small to distinguish between 99.99 and 99.9999, and there is probably no variation in packet size or content to help push the test to the edge. Think of this another way - imagine you want to do quality tests on a bunch of cables, and you don't have the proper test tools to make direct electrical measurements. You might be comparing samples between different brands, or looking for slightly defective cables in a large batch. What program could you run that would give a useful metric for transmission quality? Granted, it may be that all of the cables are "more than good enough", so that there is no correspondence between cable quality and dropped/corrupted packets, in which case no difference could be measured. That's an OK outcome. But if there is such a correspondence, and it is small, what tool would you use to see it? One that would at the end of the process allow you to say "this cable is unacceptable because it measures >4 sigmas below the mean for the batch". Such a cable would probably be perfectly acceptable for a desktop connection, it just isn't the one you want shuffling data day and night in a cluster. (Same argument for NICs and switch ports.) Thanks, David Mathog mathog at caltech.edu Manager, Sequence Analysis Facility, Biology Division, Caltech
- Previous message: [Beowulf] test network link quality?
- Next message: [Beowulf] which 24 port unmanaged GigE switch?
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
More information about the Beowulf mailing list