Jim Lux James.P.Lux at jpl.nasa.govWed Oct 19 20:00:46 PDT 2005
- Previous message: [Beowulf] flange clearance on sliding rails
- Next message: [Beowulf] looking for a few good parts
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
At 04:13 PM 10/19/2005, David Mathog wrote: >We have two racks in the machine room. They are both generic >(ie, not from a major manufacturer like Dell, Sun, or IBM.) >Neither one of them will hold a set of sliding rails properly. This is a real common problem (TM) with sliding rails in general. A couple things to check.. Just to get terminology defined: The part attached to the equipment I'll call the sliding part The part attached to the rack, I'll call the fixed part. The x axis is across the front of the rack The y axis is back through the rack The z axis is vertical Now, some dimensions to check... In theory, the front panel of the equipment should be <19" wide In theory, the equipment width should be <17" wide (that is, there should be an inch from the outside of the box to the end of the flange). In theory, there should be 17.75" clearance between the inner edges of the mounting flanges In theory, the center to center distance for the holes should be 18.3125" (that is, 18 5/16") In theory, the holes are 10-32, and spaced 5/8"-5/8"-1/2" repeating You'll also see racks with 1/4" or so clearance holes drilled in this pattern, and you put "speed clips" at the appropriate places or backing nuts (ick!). OK.. here's the practical experience.. The fixed part has a right angle at the end which is supposed to mount to the vertical rails. It mounts on the INSIDE of the rail (i.e. from the front of the rack, the fixed part is entirely behind the plane of the vertical rails. Sometimes, the vertical rail has its bend (moving from the xz plane to the yz plane) too close to the inside. You get out your trusty rotozip, dremel, or hacksaw and shorten the little tabs sticking out from the fixed part of the slides. Some of these things have weird looking spacers or a sort of combination nut (a piece of metal 1/8" thick, about 3/8" by 4", with 4 tapped holes in the appropriate spacing). If your rack has tapped holes, and you want to use the funky nut, you have to drill out the holes in the rack to clear the 10-32 hardware. If you have clearance holes, you use the 4 holed thing as a sort of clamp to hold the slides in place (since the slide prongs will typically have slots that are somewhat bigger than the hardware). In general, stuff that's mounted on slides doesn't push in as far as stuff that's mounted flush (because either the bracketry gets in the way, or the screw heads stick out, etc. Once you've got the stuff on the slides, then you have to slide it in and see if the holes in the faceplate line up with the holes in the rack, so you can secure the equipment into the rack. If they don't line up, then you have to move the brackets (having racks with removable sides helps a lot, because you can then reach the screws holding the fixed part of the slides. Some blocks of wood, wedges, and a rubber mallet are very useful in getting the "fine" adjustment. pray that your slides don't have too much junk in the back. Sometimes they have an adjustable sliding thing on the fixed part to hold the back end of the slides. The screws that hold that in place often get in the way of internal rack structure. As you can tell, this is why "rack and stack" is hardly as easy as one has been led to believe. It's also why some brands of racks are a lot easier to work with than others. An extra half inch of clearance makes a world of difference when trying to snake that screwdriver in along side something. We do a lot of stuff where we use a pair of pieces of 2x2 inch angle (1/16" steel or 1/8" aluminum) that act as shelves along the side (the edges of the equipment chassis sits on the little shelf on each side. (using the formerly described coordinate system, one leg of the angle is in the +z direction, the other in the +x, with the length in the y direction. The other side has one leg in +z, and one leg in -x. There's a hole drilled in the angle (the +z leg) that matches with a hole in the flange of the rails, or in an added piece of strut inside the rack. (Unistrut or equivalent, is very nice for this.. you mount 4 pieces, 2 on each side, the height of the rack. Then, you bolt your slide/shelves to the unistrut. >When I set mine up I pushed the forward vertical rails >all the way to the front of the case. That didn't cause any problems >with the flanges on the nodes which are permanently mounted. However >the flanges on the ends of rails hit a structural member on >the front/outside of the case. So the rails are displaced >inwards a couple of millimeters andthe resulting space is >about 4 mm too narrow to hold a case. Dremel tools are your friend. >The other rack, from another group, has the same problem on one >side. For that one (square holes with the little clamp in nuts) >there's absolutely nothing to adjust. What's most infuriating about >this case is that there's almost 2 inches of free space on the other >side, all they had to do was to make the narrower rail a tiny bit >wider, and the wider one a tiny bit narrower. > >In both cases the mounting flanges are only about 2 mm too wide. >I've seen this now with rails from two different sources. > >Is this a common problem? > >Does somebody make sliding rails which have flanges that are >just a bit narrower? > >At the moment we only need to mount one set of rails so I >guess we'll have to take it over to the metal shop and have >them cut or grind 2 mm off of the flange on one side. > >Thanks, > >David Mathog >mathog at caltech.edu >Manager, Sequence Analysis Facility, Biology Division, Caltech >_______________________________________________ >Beowulf mailing list, Beowulf at beowulf.org >To change your subscription (digest mode or unsubscribe) visit >http://www.beowulf.org/mailman/listinfo/beowulf James Lux, P.E. Spacecraft Radio Frequency Subsystems Group Flight Communications Systems Section Jet Propulsion Laboratory, Mail Stop 161-213 4800 Oak Grove Drive Pasadena CA 91109 tel: (818)354-2075 fax: (818)393-6875
- Previous message: [Beowulf] flange clearance on sliding rails
- Next message: [Beowulf] looking for a few good parts
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
More information about the Beowulf mailing list