[Beowulf] /. Cooler room or cooler servers?
Many of your questions may have already been answered in earlier discussions or in the FAQ. The search results page will indicate current discussions as well as past list serves, articles, and papers.
David Mathog mathog at mendel.bio.caltech.eduThu Apr 7 17:46:00 PDT 2005
- Previous message: [Beowulf] block runing jobs individually on each node
- Next message: [Beowulf] /. Cooler room or cooler servers?
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
> From: "Robert G. Brown" <rgb at phy.duke.edu> > > Thats dual 32bit xeons, the dual em64t xeon systems are more like 420W. > > > > Michael > > Wow, that's Hot. That's actually getting up there to the old alpha > boxen, per CPU. So 40 1U systems are order of 16 KW/rack? Five tons of > AC per rack? $400/year/box for power and cooling (or thereabouts)? > Oooo. Convert 16KW to horsepower and find 16000 * .00134 => 214 hp. The point being that car engines generate this much heat in an even smaller space (1/3 to 1/4 of a rack volume, including the block and not just the cylinders). Automobile engineers resolve this issue by dumping the heat as fast as they possibly can. It's interesting to compare and contrast the way a car motor is cooled with the way a computer is cooled. 1. Car motors are cooled by ambient input air - I've never seen a car that prechills its cooling air. Nor is the cooling air blowing over the radiator particularly clean. 2. There have been smallish air cooled motors but I can't think of any car motors over 200 hp that were air cooled. Aircraft motors that big may be aircooled but in that case there is typically in excess of 100 kph in air flow available. So expect either wind tunnel speeds for computer cooling air or water cooling. 3. There comes a point where there is so much heat produced it simply doesn't make sense to try to cool the outlet air and run it back around to the input. Instead the hot air is blown directly out of the building, with care taken to keep it away from the intakes. In which case either the computer needs to be able to breathe (what would now be considered) very dirty air or the intake system needs to filter a lot of particulates out very quickly. For sites where the weather get really hot it might still be necessary to cool the ambient intake air on some days, since 100F air is really too hot to cool a CPU or disk drive effectively. Perhaps we should be looking forward to chimneys and/or cooling towers in future computer room designs? Regards, David Mathog mathog at caltech.edu Manager, Sequence Analysis Facility, Biology Division, Caltech
- Previous message: [Beowulf] block runing jobs individually on each node
- Next message: [Beowulf] /. Cooler room or cooler servers?
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
More information about the Beowulf mailing list