Dual Athlon MP 1U units
Many of your questions may have already been answered in earlier discussions or in the FAQ. The search results page will indicate current discussions as well as past list serves, articles, and papers.
Robert G. Brown rgb at phy.duke.eduSat Jan 26 16:26:07 PST 2002
- Previous message: Dual Athlon MP 1U units
- Next message: Dual Athlon MP 1U units
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
On Sat, 26 Jan 2002, Bari Ari wrote: > VA = amps × volts > VA = watts ÷ power factor > watts = VA × power factor > amps = watts ÷ (volts × power factor) > > "Power factor" is a number between zero and one representing the portion > of the power drawn by a system that actually delivers energy to the > system. A system with a power factor of one (sometimes called "unity" > power factor) is making full use of the energy it draws. A system with a > power factor of 0.75 is effectively using only three-quarters of the > energy it draws. Typical PC power supplies are not power factor Dear Bari, I liked all of your description except that of the power factor. As I understand it, the power factor is the cosine of the phase difference between the line voltage and the drawn current. When they are in phase, the (rms) VA = the actual power consumed, in watts, as it is in a light bulb. When they are \pi/2 out of phase (as they are for e.g. a perfect capacitor or inductor hooked across an AC power supply) the VA can be quite high (depending on the impedance of the circuit element) but the power factor can be zero! No power is actually delivered to the circuit, on average -- energy is stored in the capacitor and then given back to the line. It does not actually appear as heat in the room. Real loads are generally somewhere in between. Loads that are "mostly resistive" have the highest power factors and only the resistive "part" appears as heat; loads that are capacitive or inductive can have current that lags or leads the voltage and draw less power than one might think looking at the peak voltage and current. The peak voltage and current are still important, of course. The power delivery lines do have to be able to handle the peak current as they burn energy as (1/2) I^2 R_line for that peak current. rgb -- Robert G. Brown http://www.phy.duke.edu/~rgb/ Duke University Dept. of Physics, Box 90305 Durham, N.C. 27708-0305 Phone: 1-919-660-2567 Fax: 919-660-2525 email:rgb at phy.duke.edu
- Previous message: Dual Athlon MP 1U units
- Next message: Dual Athlon MP 1U units
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
More information about the Beowulf mailing list