alvin at Mail.Linux-Consulting.com alvin at Mail.Linux-Consulting.comWed May 23 14:43:35 PDT 2001
- Previous message: custom cluster cabinets (was Re: 1U P4 Systems)
- Next message: custom cluster cabinets -- cooling
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
hi ya thank kevin for the url... nice looking chassis but... i dont know if theyve solved the cooling problem per se since we've nto measured/tested it... adding blowers/fans does NOT mean that its cooler if there is no air coming in and out of the chassis designing 8 servers inside a 1U shelf space is a challenge and must be accompanied by a similarly sized budget and if off-the-shelf 8 servers in 1U space is required... a cool crusoe based system might work if its not too compute intensive... have fun alvin On Wed, 23 May 2001, Bari Ari wrote: > Kevin Facinelli wrote: > > > If the entire top of the case was a heatsink many > > other variable come to mind....what happens when you > > stack or rack??? how thick will the lid be? How would > > you get air across the lid in a racked configuration. > > > > Let's think about this??? why does it have to be > > 1U??...think a little bit outside the box...if the > > unit could be any shape would it be thin and narrow > > creating a terrible aspect ratio for air > > movement...NO. > > > > Take a look at the ingenious approach of this product: > > > > http://www.crystalpc.com/products/computers/cs300.asp > > > > The cooling and space advantages are easy to see. > > > > > Take a look at the earlier post, it's all worked out. > > The Crystal approach equates to only .87U per server, "the CS300 lets > you fit up to 52 servers in a standard 7 ft. rack/cabinet", better but > not dense enough. We were targeting 0.125U per node or 384 nodes per 7 > ft. rack. I'd probably never build a single board to fill a 1U with > eight P4s on it, but the numbers do work out if you wanted to build some. > > Bari > > > > _______________________________________________ > Beowulf mailing list, Beowulf at beowulf.org > To change your subscription (digest mode or unsubscribe) visit http://www.beowulf.org/mailman/listinfo/beowulf >
- Previous message: custom cluster cabinets (was Re: 1U P4 Systems)
- Next message: custom cluster cabinets -- cooling
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
More information about the Beowulf mailing list